Semi-conductive Nylon (Polyester Woven) tape

Description:Semi-conductive Nylon (Polyester Woven) tape

Composition:Nylon Fabric

                      Semi-conductive bonder

Application:Separating, binding /Between Power cable components

9.png


Property

Unit

YSCN-10

YSCN-12

YSCN-14

Test method

Thickness

 mm

0.10±0.02

0.12±0.02

0.14±0.02

ISO 9073-2

Mass per unit area

 g/m2

80±10

90±10

100±10

ISO 9073-2

Tensile strength

N/cm

³120

³140

³160

ISO 9073-3

Elongation

 %

³25

³25

³25

ISO 9073-3

Short term   stability

  °C

230

230

230

YS Method

Long term stability

  °C

145

145

145

IEC 216

Surface Resistance

 W

£1000

£1000

£1000

DIN53482

Volume Resistance

W.cm

6

6

6

DIN54345

Moisture content

  %

£9

£9

£9

ISO 287